| Service Type | Annual Maintenance Contract |
| Coverage | UPS Systems, Inverter Batteries (All Brands) |
| Plans | Basic, Standard, Comprehensive |
| Response Time | 4–24 Hrs (Priority Support) |
| Inspection Frequency | Quarterly / Half-yearly / Custom |
| Key Benefits | Max Uptime, Battery Life Extension |

Comprehensive maintenance plans for uninterrupted power backup across industries and homes
Regular inspections, battery health checks, terminal cleaning & voltage calibration to avoid sudden failures.
Emergency response for UPS & inverter failures ensuring zero downtime for critical operations.
Expert load testing, water top-up (lead-acid), and deep discharge protection for longer backup life.
Detailed analytics, efficiency tracking & custom recommendations after each service visit.
UPS & Inverter Battery AMC (Annual Maintenance Contract) provides complete and proactive care for your power backup systems through regular inspections, performance monitoring, and quick fault resolution. It includes services like voltage regulation, battery health diagnostics, inverter efficiency optimization, and emergency part replacement, ensuring uninterrupted performance and longer equipment life.
This service is ideal for both industries and residential use, including manufacturing units, data centers, hospitals, retail stores, apartments, and villas. Certified engineers handle multi-brand UPS systems and perform advanced maintenance tasks such as load testing, thermal analysis, and battery bank optimization to ensure reliable power during outages.
The AMC plan typically covers periodic health checkups, battery terminal cleaning with anti-corrosion treatment, testing of inverter components like IGBT and capacitors, and firmware updates. It also includes priority support for breakdown calls, ensuring fast response and minimal downtime whenever an issue occurs.
| AMC Parameter | Detailed Coverage / Specification |
|---|---|
| Service Scope | All makes & models of Offline/Line-interactive/Online UPS, Inverter + Battery banks (SMF, Tubular, Lead-Acid, Lithium-ion) |
| Plans Offered | Basic (2 visits/year), Standard (4 visits + 8hrs response), Comprehensive (Unlimited visits + 4hrs response + Parts discount) |
| Preventive Tasks | Visual inspection, voltage & frequency calibration, battery impedance test, load bank test, thermal scan, cleaning, terminal torque check |
| Battery Maintenance | Electrolyte top-up (flooded batteries), specific gravity check, float voltage adjustment, deep discharge prevention, corrosion removal |
| Corrective Actions | Fault diagnosis, PCB repair/replacement, fan replacement, battery swapping, wiring harness repair, inverter relay check |
| Response SLA | Basic: 24-48 hrs / Standard: 8-12 hrs / Comprehensive: 2-4 hrs (urban) same-day for critical sites |
| Reporting | Digital service report with recommendations, battery aging analysis, and efficiency trends |
| Exclusions | Consumables (batteries beyond 1 year old, external cabling) but offered at discounted rates |
| Certifications | ISO 9001 certified engineers, factory-trained support teams, genuine spare parts guarantee |
*Custom AMC contracts available for large-scale deployments. Contact INDUS for bulk pricing.